Pantera Pro

Image
Pantera Pro
Pantera Pro Semi-Compliant Workhorse Balloon
Image
Pantera Pro
Pantera Pro Semi-Compliant Workhorse Balloon
Image
Pantera Pro
Pantera Pro Semi-Compliant Workhorse Balloon
Image
Pantera Pro
Pantera Pro Semi-Compliant Workhorse Balloon

Pantera Pro

SEMI-COMPLIANT WORKHORSE BALLOON
INDICATED FOR DILATATION OF CORONARY ARTERY OR BYPASS GRAFT STENOSIS

Challenging lesions require a versatile workhorse balloon. Be it a tight lesion or a complex bifurcation, Pantera Pro offers the performance to reach, cross and dilate.


KEY FACTS
  • Outstanding crossability in tight lesions1
  • 43% less friction during kissing balloon technique2
  • 38% more push to reach target lesion3

 

Product Details

Outstanding Crossability in Tight Lesions1

The proprietary balloon material for small sizes enables slim balloon shoulders while maintaining durability. Coupled with the newly hydrophilic balloon coating, Pantera Pro excels in tight lesions.


43% Less Friction during Kissing Balloon Technique2

The reduced distal shaft profile lowers friction when using two balloons in a 6F guiding catheter.
(Any combination of two diameters not larger than 3.5mm within a 6F guiding catheter with a minimal inner diameter of 0.070"/1.78mm).


38% More Push to Reach Target Lesion3

BIOTRONIK’s unique Enhanced Force Transmission shaft delivers optimal pushability due to the direct transition from proximal metallic hypotube to distal guide wire support section.


Technical Data

Proximal Shaft
Design
Hypotube design

Diameter
2.0F
Shaft markers 92cm and 102cm from tip
Distal Shaft
Guiding catheter 5F (min. I.D. 0.056" / 1.42mm)
Guide wire diameter 0.014"
Lesion entry profile 0.017"
Usable length 140 cm
Balloon material Semi-crystalline co-polymer
Balloon folding ø 1.25 - 1.5mm: Two-fold; ø 2.0 - 4.0mm: Tri-fold
Balloon markers Platinum-iridium: ø 1.25 - 1.5mm one marker; ø 2.0 - 4.0mm two markers
Coating distal shaft Hydrophilic (end of balloon to guide wire exit port)
Balloon and tip coating ø 1.25 - 2.0mm: Hydrophilic
ø 2.50 - 4.0 mm: Hydrophobic
Kissing balloon technique 6F guiding catheter (min. I.D. 0.070"/1.78 mm), up to ø 3.5mm
Diameter 2.6F (ø 1.25 - 2.0mm); 2.7F (ø 2.5 - 3.5mm); 2.9F (ø 4.0mm)

Compliance Chart

Balloon Diameter x Length (mm)
Nominal Pressure atm4 7 7 7 7 7 7 7
(NP) ø (mm) 1.24 1.49 2.01 2.49 3.08 3.62 3.95
Rated Burst Pressure atm4 14 14 14 14 14 14 14
(RBP) ø (mm) 1.37 1.72 2.23 2.93 3.5 4.06 4.55

Ordering Information


Contact

contact
Country/Region
3 + 0 =
Solve this simple math problem and enter the result. E.g. for 1+3, enter 4.

1.25 - 2.0mm diameter, when compared to key competitors. BIOTRONIK data on file.

2 vs Trek (Abbott), BIOTRONIK data on file.

3 vs Mini Trek (Abbott), BIOTRONIK data on file.

4 1 atm = 1.013 bar