Vascular Intervention // Peripheral
Balloon-Expandable Cobalt Chromium Stent System/0.014”/Rx
Dynamic Renal
Proximal gold marker for superior visibility to support accurate stent placement
Cobalt chromium alloy combining a lower profile with high radial force
Double helix stent design for high flexibility
Proximal gold marker for superior visibility to support accurate stent placement
The gold plated proximal stent ring element facilitates superior visibility allowing accurate ostial stent placement.
Cobalt chromium alloy combining a lower profile with improved radial force
The cobalt chromium alloy thin strut stent design permits a low crossing profile, while maintaining radial force for vessel scaffolding.
Double helix stent design for high flexibility
The double helix stent design ensures high flexibility, homogeneous wall coverage and superb conformability.
proBIO coating for improved stent surface biocompatibility1
TheproBIOsilicon carbide coating acts as a barrier between the metal stent and the surrounding tissue and blood, protecting the surface of the stent. By providing a barrier against ion release, the coating creates a surface that reduces platelet aggregation while facilitating endothelialization.1
Deliverability
Indicated for improving arterial luminal diameter in patients with clinical symptoms attributable to atherosclerotic stenosis of the renal arteries.
Technical Data
Dynamic Renal Stent | |
---|---|
Stent | Balloon-expandable |
Stent material | Cobalt chromium (L605) |
Strut thickness | 120 μm (ø 4.5 - 5.0 mm) 140 μm (ø 6.0 - 7.0 mm) |
Stent coating | proBIO (Amorphous Silicon Carbide) |
Stent marker | Proximal gold marker |
Sizes | ø 4.5 - 7.0 mm; L: 12 - 19 mm |
Delivery system | |
---|---|
Catheter type | Rapid exchange (Rx) |
Recommended guide wire | 0.014" |
Tip | Soft, short and tapered |
Balloon markers | 2 swaged markers |
Shaft (proximal) | Hydrophobic coating |
Usable length | 140 cm |
Nominal pressure (NP) | 10 atm |
Rated burst pressure (RBP) | 15 atm (ø 4.5 - 6.0 mm) 13 atm (ø 7.0 mm) |
Compliance Chart
Balloon Diameter x Length (mm) | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal Pressure | atm3 | 10 | 10 | 10 | 10 | ||||||||||||||
NP | ø (mm) | 4.5 | 5.0 | 6.0 | 7.0 | ||||||||||||||
Rated Burst Pressure | atm3 | 15 | 15 | 15 | 13 | ||||||||||||||
RBP | ø (mm) | 4.7 | 5.3 | 6.2 | 7.2 |
Ordering Information
Stent ø (mm) | Catheter length 140 cm | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4.5 (4F) | 358582 | 368711 | 358586 | ||||||||||
5.0 (4F) | 358583 | 368712 | 358587 | ||||||||||
6.0 (5F) | 358584 | 368713 | 358588 | ||||||||||
7.0 (5F) | 358585 | 368714 | 358589 |
Contact
1 Rzany A, Schaldach M. Smart Material Silicon Carbide: Reduced Activation of Cells and Proteins on a-SiC:H-coated Stainless Steel. Progress in Biomedical Research 2001; May: 182-194.