Passeo-14

 

Vascular Intervention // Peripheral
PTA Balloon Catheter/0.014”/OTW

Passeo-14



     Up to 3.8 x faster deflation times

     Enhanced crossability

     High pushability and flexibility

 

 

 

 

 


Up to 3.8 x faster deflation times1

Due to the coaxial catheter shaft design that creates a large balloon lumen facilitating rapid inflation and deflation, Passeo-14 deflates:

3.8 x faster than Amphirion Deep
2.0 x faster than Coyote
2.4 x faster than NanoCross



 

 

 

 

 

 

 

 


The solution for dedicated below the ankle sizes

 

 

 

 

  • ø 1.5 - 2.0 mm
  • 150 mm flexible distal shaft
  • Tailored stiffening wire







Enhanced crossability

The tri-fold balloon, which is fully coated when folded and only partly coated when inflated, enables an enhanced crossability while minimizing slippage during inflation.








High pushability and flexibility2

Impressive pushability due to catheter shaft design featuring a unique stiffening wire in the proximal shaft of the catheter, while enabling high flexibility due to a lower profile distal shaft in small, tortuous vessels.

 

 

 


 

 

Passeo-14


Indicated for balloon dilatation of the stenotic portion of a lower limb artery for the purpose of improving perfusion.

 

 
 
 
 

Technical Data

 
Passeo-14 Balloon catheter
Catheter type OTW
Recommended guide wire 0.014"
Tip Optimized entry profile and colored
Balloon material SCP (semi-crystalline polymer), controlled compliance (4 - 6%)
Balloon folding 3-fold
Balloon coating Hydrophilic patchwork coating
Balloon markers 2 swaged markers (zero profile)
Sizes ø 1.5 - 4.0 mm; L: 20 - 220 mm
Distal shaft 3.1 F, hydrophilic coating, coaxial design; 150 mm length (ø 1.5/2.0 x 20 - 100 mm); 75 mm length (ø 2.0 x 140 - 220 mm and ø 2.5 - 4.0 mm)
Proximal shaft 3.9 F, hydrophobic coating, coaxial design; stiffening wire
Usable length 150 cm (ø 1.5 - 4.0 mm); 120 cm (ø 1.5 - 2.0 mm); 90 cm (ø 2.5 - 4.0 mm)
 
 
 

Compliance Chart

 
    Balloon Diameter x Length (mm)
Nominal Pressure atm5 7 7 7 7 7 7
(NP) ø (mm) 1.5 2.0 2.5 3.0 3.5 4.0
Rated Burst Pressure atm5 14 14 14 14 14 14
(RBP) ø (mm) 1,57 2,08 2,61 3,18 3,63 4,16
 
 
 

Ordering Information

 

Catheter Length (cm)

 

Balloon     Balloon Length 

ø (mm)        ø (mm)     

      20 40 70 100 140 180 220
120 (4F)   1.5         3802716 380277 380283 - - - -
120 (4F)   2.0 - 380278 380284 380290 380296 380302 380308
90 (4F)   2.5 - 380279 380285 380291 380297 380303 380309
90 (4F)   3.0 - 380280 380286 380292 380298 380304 380310
90 (4F)   3.5 - 3802816 3802876 3802936 3802996 - -
90 (4F)   4.0 - 380282 380288 380294 380300 - -
 

Catheter Length

(cm) 

 

Balloon     Balloon Length 

ø (mm)        ø (mm)      

 
      20 40 70 100 140 180 220
150 (4F)   1.5 3803136 380319 380325 - - - -
150 (4F)   2.0 - 380320 380326 380332 380338 380344 380350
150 (4F)   2.5 - 380321 380327 380333 380339 380345 380351
150 (4F)   3.0 - 380322 380328 380334 380340 380346 380352
150 (4F)   3.5 - 3803236 3803296 3803356 3803416 - -
150 (4F)   4.0 - 380324 380330 380336 380342 - -

Contact

contact
Country/Region

1 BIOTRONIK data on file. Volume adjustment: A 3mm x 120mm balloon contains 17% less contrast media volume than a 3mm x 140mm balloon. The measured deflation time of a 3mm x 140mm balloon was adjusted by 17 % to make a direct competitive comparison;

2 BIOTRONIK Data on file.
Amphirion is a registered trademark of the Medtronic Group of Companies; Armada is a registered trademark of Abbott; Coyote is a registered trademark of Boston Scientific; NanoCross is a registered trademark of Medtronic Group of Companies.