Pantera Pro

Image
Pantera Pro
Pantera® Pro Semi-Compliant Workhorse Balloon
Image
Pantera Pro
Pantera® Pro Semi-Compliant Workhorse Balloon
Image
Pantera Pro
Pantera® Pro Semi-Compliant Workhorse Balloon
Image
Pantera Pro
Pantera® Pro Semi-Compliant Workhorse Balloon

Pantera® Pro

SEMI-COMPLIANT WORKHORSE BALLOON

Indicated for dilatation of coronary artery or bypass graft stenosis. Challenging lesions require a versatile workhorse balloon. Be it a tight lesion or a complex bifurcation, Pantera® Pro offers the performance to reach, cross and dilate.


KEY FACTS
  • Outstanding crossability in tight lesions1
  • 43% less friction2 during kissing balloon technique
  • 38% more push3 to reach target lesion

 

Product Details

Outstanding Crossability in Tight Lesions1

The proprietary balloon material for small sizes enables slim balloon shoulders while maintaining durability. Coupled with the newly hydrophilic balloon coating, Pantera Pro excels in tight lesions.


43% Less Friction2 during Kissing Balloon Technique

The reduced distal shaft profile lowers friction when using two balloons in a 6 F guiding catheter.
(Any combination of two diameters not larger than 3.5 mm within a 6F guiding catheter with a minimal inner diameter of 0.070"/1.78 mm.


38% More Push3 to Reach Target Lesion

BIOTRONIK’s unique Enhanced Force Transmission shaft delivers optimal pushability due to the direct transition from proximal metallic hypotube to distal guide wire support section.


Technical Data

Proximal Shaft
Design
Hypotube design

Diameter
2.0F
Shaft markers 92 cm and 102 cm from tip
Distal Shaft
Guiding catheter 5F (min. I.D. 0.056" / 1.42mm)
Guide wire diameter 0.014"
Lesion entry profile 0.017"
Usable length 140 cm
Balloon material Semi-crystalline co-polymer
Balloon folding ø 1.25 - 1.5 mm: Two-fold; ø 2.0 - 4.0 mm: Tri-fold
Balloon markers Platinum-iridium: ø 1.25 - 1.5 mm one marker; ø 2.0 - 4.0 mm two markers
Coating distal shaft Hydrophilic (end of balloon to guide wire exit port)
Balloon and tip coating ø 1.25 - 2.0 mm: Hydrophilic
ø 2.50 - 4.0 mm: Hydrophobic
Kissing balloon technique 6 F guiding catheter (min. I.D. 0.070"/1.78 mm), up to ø 3.5 mm
Diameter 2.6 F (ø 1.25 - 2.0 mm); 2.7 F (ø 2.5 - 3.5 mm); 2.9 F (ø 4.0 mm)

Compliance Chart

Balloon Diameter x Length (mm)
Nominal Pressure atm4 7 7 7 7 7 7 7
(NP) ø (mm) 1.24 1.49 2.01 2.49 3.08 3.62 3.95
Rated Burst Pressure atm4 14 14 14 14 14 14 14
(RBP) ø (mm) 1.37 1.72 2.23 2.93 3.5 4.06 4.55

Ordering Information


Contact

contact
Country/Region

1 1.25 - 2.0 mm diameter, when compared to key competitors. BIOTRONIK data on file.

2 vs Trek (Abbott), BIOTRONIK data on file.

3 vs Mini Trek (Abbott), BIOTRONIK data on file.

4 1 atm = 1.013 bar

Pantera is a trademark or registered trademark of the BIOTRONIK Group of Companies.