Passeo-14

Image
Image of Passeo-14
Passeo-14 PTA Balloon
Image
Image of Passeo-14
Passeo-14 PTA Balloon
Image
Image of Passeo-14
Passeo-14 PTA Balloon
Image
Image of Passeo-14
Passeo-14 PTA Balloon

Passeo®-14

PTA BALLOON

Indicated for lower limb arteries. Up to 73% faster deflation time1 due to state-of-the-art catheter shaft design that creates a large balloon lumen, facilitating rapid inflation and deflation. A faster approach to treating long lesions.


KEY FACTS
  • Up to 73% faster deflation times2
  • The only forefront solution offering dedicated pedal sizes
  • Enhanced crossability
  • High pushability and flexibility

 

Product Details

Passeo-14 image

Fast Deflation Times

Passeo-143 deflates:

  • 73% faster than Amphirion Deep
  • 36% faster than Coyote
  • 24% faster than NanoCross

Delivering you the only forefront dedicated pedal design of:

  • ø 1.5 - 2.0 mm
  • 150 mm flexible distal shaft
  • tailored stiffening wire

Enhanced Crossability

The tri-fold balloon which is fully coated when folded and only partly coated when inflated enables an enhanced crossability while minimizing slippage during inflation.


Passeo-14 image

Rapid Deflation Time

A large balloon in-/deflation lumen is being created due to the leading-edge coaxial catheter shaft design. This enables a contrast media solution to be channeled more easily.


Passeo-14 image

High Pushability and Flexibility4

Impressive pushability delivered by novel catheter shaft design, featuring a unique stiffening wire design in the proximal shaft of the catheter, while also enabling superior flexibility due to a lower profile distal shaft design.


Technical Data

Passeo®-14 Balloon catheter
Catheter type
OTW
Recommended guide wire
0.014"
Tip
Optimized entry profile and colored
Balloon material
SCP (semi-crystalline polymer), controlled compliance (4 - 6%)
Balloon folding
3-fold
Balloon coating
Hydrophilic patchwork coating
Balloon markers
2 swaged markers (zero profile)
Sizes
ø 1.5 - 4.0 mm; L: 20 - 220 mm
Distal shaft
3.1 F, hydrophilic coating, coaxial design; 150 mm length (ø 1.5/2.0 x 20 - 100 mm); 75 mm length (ø 2.0 x 140 - 220 mm and ø 2.5 - 4.0 mm)
Proximal shaft
3.9 F, hydrophobic coating, coaxial design; stiffening wire
Usable length
150 cm (ø 1.5 - 4.0 mm); 120 cm (ø 1.5 - 2.0 mm); 90 cm (ø 2.5 - 4.0 mm)

Compliance Chart

Balloon Diameter x Length (mm)
Nominal Pressure atm5 7 7 7 7 7 7
(NP) ø (mm) 1.5 2.0 2.5 3.0 3.5 4.0
Rated Burst Pressure atm5 14 14 14 14 14 14
(RBP) ø (mm) 1,57 2,08 2,61 3,18 3,63 4,16

Ordering Information


Contact

contact
Country/Region

1 BIOTRONIK data on file (IIB report 65/2012)

2 vs. Amphirion Deep

3 Volume correction: the volume of a 3x120 mm balloon is 15% less than the volume of the 3x140 mm balloon, which can be directly correlated to deflation time. Therefore, the measured deflation time of 32% can be reduced by 15%, resulting in a volume-corrected deflation time of 27%.

4 BIOTRONIK data on file (IIB report 65/2012).

5 1 atm = 1.013 bar

6 8 weeks pre-order only

Passeo is a trademark or registered trademark of the BIOTRONIK Group of Companies.