Pantera Leo

 

Vascular Intervention // Coronary
Non-Compliant High Pressure Balloon Catheter

Pantera LEO


   Lowest compliance in class avoiding dog-bone effect

   Precise dilatation

   Enhanced crossability and accurate placement

 

 

 

 

 


Lowest compliance in class1 avoiding dog-bone effect


The Pantera LEO high pressure balloon has the lowest compliance in class1 which ensures controlled minimal growth up to Rated Burst Pressure (RBP) without any dog-bone effect.

 

 

 

 

 


More controlled growth from Nominal Pressure (NP) to RBP1


Compliance curves 3.0 mm balloons
(Values shown between NP and RBP)

 

 

 

 



Source: Product Labelling






Precise dilatation

 

 


Extra short ballooon shoulders


The extra short balloon shoulders reduce longitudinal balloon growth, minimizing the potential for vessel trauma outside the treatment area.

Longitudinal balloon growth between NP and RBP2

 

 









Enhanced crossability and accurate placement

 

 


Patchwork coating

The tri-fold balloon is fully coated when folded but only partially coated when inflated. The resulting patchwork coating enables enhanced crossability while minimizing slippage during dilatation.



 

 

 

 

 

 


 

 

 

 

 

Pantera LEO

 


Indicated for stent post-dilatation and dilatation of a coronary artery or bypass graft stenosis.*

 

 

 

 
 
 
 

Technical Data

 
Proximal Shaft
Design Hypotube design
Diameter 2.0F
Shaft markers 92 cm and 102 cm from tip
Coating Hydrophobic
 
Distal Shaft
Guiding catheter 5F (min. I.D. 0.056”)
Guide wire diameter 0.014”
Lesion entry profile 0.018”
Usable length 145 cm
Distal shaft length 34 cm
Balloon material SCP (Semi Crystalline Polymer)
Balloon folding 3-fold
Balloon markers Platinum-iridium
Coating Hydrophilic (end of balloon to GW exit port); hydrophobic (balloon and tip)
Diameter 2.6F (ø 2.0 - 3.75 mm); 2.7F (ø 4.0 - 5.0 mm)
 
 
 

Compliance Chart

 

Ordering Information

 
       
2.0   366991 367002 367013 367024 367035
2.25   366992 367003 367014 367025 367036
2.50   366993 367004 367015 367026 367037
2.75   366994 367005 367016 367027 367038
3.00   366995 367006 367017 367028 367039
3.25   366996 367007 367018 367029 367040
3.50   366997 367008 367019 367030 367041
3.75   366998 367009 367020 367031 367042
4.00   366999 367010 367021 367032 367043
4.50   367000 367011 367022 367033 367044
5.00   367001 367012 367023 367034 367045

Contact

contact
Country/Region

1 When compared to main competitors, compliance curves 3.0 mm balloons, BIOTRONIK Data on file;

2 BIOTRONIK Data on file.

Trek and NC Trek are registered trademarks of Abbott; Emerge is a registered trademark of Boston Scientific; Euphora is a registered trademark of Medtronic.

*Indication as per IFU.