Vascular Intervention // Coronary
Non-Compliant High Pressure Balloon Catheter
Pantera LEO
Lowest compliance in class avoiding dog-bone effect
Precise dilatation
Enhanced crossability and accurate placement
Lowest compliance in class1 avoiding dog-bone effect
The Pantera LEO high pressure balloon has the lowest compliance in class1 which ensures controlled minimal growth up to Rated Burst Pressure (RBP) without any dog-bone effect.
More controlled growth from Nominal Pressure (NP) to RBP1
Compliance curves 3.0 mm balloons
(Values shown between NP and RBP)
Source: Product Labelling
Precise dilatation
Extra short ballooon shoulders
The extra short balloon shoulders reduce longitudinal balloon growth, minimizing the potential for vessel trauma outside the treatment area.
Longitudinal balloon growth between NP and RBP2
Enhanced crossability and accurate placement
Patchwork coating
The tri-fold balloon is fully coated when folded but only partially coated when inflated. The resulting patchwork coating enables enhanced crossability while minimizing slippage during dilatation.
Indicated for stent post-dilatation and dilatation of a coronary artery or bypass graft stenosis.*
Technical Data
Proximal Shaft | |
---|---|
Design | Hypotube design |
Diameter | 2.0F |
Shaft markers | 92 cm and 102 cm from tip |
Coating | Hydrophobic |
Distal Shaft | |
---|---|
Guiding catheter | 5F (min. I.D. 0.056”) |
Guide wire diameter | 0.014” |
Lesion entry profile | 0.018” |
Usable length | 145 cm |
Distal shaft length | 34 cm |
Balloon material | SCP (Semi Crystalline Polymer) |
Balloon folding | 3-fold |
Balloon markers | Platinum-iridium |
Coating | Hydrophilic (end of balloon to GW exit port); hydrophobic (balloon and tip) |
Diameter | 2.6F (ø 2.0 - 3.75 mm); 2.7F (ø 4.0 - 5.0 mm) |
Compliance Chart
Ordering Information
2.0 | 366991 | 367002 | 367013 | 367024 | 367035 | |||||||||
2.25 | 366992 | 367003 | 367014 | 367025 | 367036 | |||||||||
2.50 | 366993 | 367004 | 367015 | 367026 | 367037 | |||||||||
2.75 | 366994 | 367005 | 367016 | 367027 | 367038 | |||||||||
3.00 | 366995 | 367006 | 367017 | 367028 | 367039 | |||||||||
3.25 | 366996 | 367007 | 367018 | 367029 | 367040 | |||||||||
3.50 | 366997 | 367008 | 367019 | 367030 | 367041 | |||||||||
3.75 | 366998 | 367009 | 367020 | 367031 | 367042 | |||||||||
4.00 | 366999 | 367010 | 367021 | 367032 | 367043 | |||||||||
4.50 | 367000 | 367011 | 367022 | 367033 | 367044 | |||||||||
5.00 | 367001 | 367012 | 367023 | 367034 | 367045 |