PK Papyrus

Vascular Intervention // Coronary
Covered Coronary Stent System

PK Papyrus®




  Covered single stent design

  Low crossing profile

  Exceptional deliverability
 

 


PK Papyrus

Designed to save lives when seconds count.
 


Covered single stent design

With its covered single stent design, PK Papyrus achieves greater bending flexibility and a smaller crossing profile compared to the traditional sandwich design stent, allowing you to seal perforations with confidence.


 


Low crossing profile1



 

 

 


Innovative polyurethane membrane

Electrostatic forces spin polyurethane fibers onto the stent surface, creating a thin and highly elastic membrane.





 

 

 

 

 


 

 

Exceptional deliverability

 


58% greater flexibility2



 

 


Shorter median time to deliver

Single center, retrospective investigation of 61 patients treated with covered coronary stents.3,4






“In rare cases of a coronary perforation, time is the enemy.”


Dr. Dean Kereiakes, Interventional Cardiologist and Medical Director of The Christ Hospital and Vascular Center, Cincinnati, Ohio, USA.

 

 

 

 

 


5F Compatibility

For main sizes - no need for guide catheter upgrade (ø 2.5-4.0 mm).

 

 

 

 

 

 


 

 

 

PK Papyrus

Indicated for acute coronary artery perforations.*
 

Media

PK Papyrus

This video demonstrates PK Papyrus’s key technical features, which allow physicians to seal artery perforations with confidence.


Technical Data

Stent
Stent cover materialNon-woven, electrospun polyurethane
Stent cover thickness90 μm
Stent strut thicknessø 2.5 - 3.0 mm: 60 μm (0.0024"); ø 3.5 - 4.0 mm: 80 μm (0.0031"); ø 4.5 - 5.0 mm: 120 μm (0.0047")
Stent materialCobalt chromium (L-605) with proBIO (Amorphous Silicon Carbide) coating
Maximum stent expansion diameterø 2.5 - 3.0 mm: 3.50 mm; ø 3.5 - 4.0 mm: 4.65 mm; ø 4.5 - 5.0 mm: 5.63 mm
Delivery system
Guide wire diameter 0.014"
Usable catheter length 140 cm
Recommended guide catheter ø 2.5 - 4.0 mm: 5F (min. I.D.** 0.056"); ø 4.5 - 5.0 mm: 6F (min. I.D.** 0.070")
Nominal pressure (NP) ø 2.5 - 3.5 mm: 8 atm; ø 4.0 - 5.0 mm: 7 atm
Rated burst pressure (RBP) ø 2.5 - 4.0 mm: 16 atm; ø 4.5 - 5.0 mm: 14 atm
 **I.D. = Inner Diameter

Ordering Information

2.5 (5F)369380369386-
3.0 (5F)369381369387381789
3.5 (5F)369382369388381790
4.0 (5F)369383369389381791
4.5 (6F)369384369390369392
5.0 (6F)369385369391369393

Contact

contact
Country/Region

1 Compared to Graftmaster 2.8/16 (BIOTRONIK data on file);

2 Compared to Jostent Graftmaster 3.0/16 (BIOTRONIK data on file);

3 Hernández-Enríquez M, Lairez O, Campelo-Parada F, et al. Outcomes after use of covered stents to treat coronary artery perforations. Comparison of old and new-generation covered stents. J Interv Cardiol. 2018;1–7. doi: 10.1111/joic.12525;

4 Population is representative of real world interventional practice and was not a randomized prospective clinical trial.

PK Papyrus and proBIO are trademarks or registered trademarks of the BIOTRONIK Group of Companies. Jostent and Graftmaster are trademarks or registered trademarks of the Abbott Group of Companies.

*Indication as per IFU.