PK Papyrus

Vascular Intervention // Coronary
Covered Coronary Stent System

PK Papyrus®

Designed to save lives
when seconds count.






  Covered single stent design

  Low crossing profile

  Exceptional deliverability
 

 


Covered single stent design

With its covered single stent design, PK Papyrus achieves greater bending flexibility and a smaller crossing profile compared to the traditional sandwich design stent, allowing you to seal perforations with confidence.


 


Low crossing profile1



 

 

 


Innovative polyurethane membrane

Electrostatic forces spin polyurethane fibers onto the stent surface, creating a thin and highly elastic membrane.





 

 

 

 

 


 

 

Exceptional deliverability

 


81% greater flexibility2



 

 


Shorter median time to deliver

Single center, retrospective investigation of 61 patients treated with covered coronary stents.3,4






“In rare cases of a coronary perforation, time is the enemy.”


Dr. Dean Kereiakes, Interventional Cardiologist and Medical Director of The Christ Hospital and Vascular Center, Cincinnati, Ohio, USA.

 

 

 

 

 


5F Compatibility

For main sizes - no need for guide catheter upgrade (ø 2.5-4.0 mm).

 

 

 

 

 

 


 

 

 

PK Papyrus

PKP is indicated for the treatment of acute coronary artery perforations.
 

Media

PK Papyrus

This video demonstrates PK Papyrus’s key technical features, which allow physicians to seal artery perforations with confidence.


Technical Data

Stent
Stent cover material Non-woven, electrospun polyurethane
Stent strut thickness ø 2.5 - 3.0 mm: 60 μm (0.0024"); ø 3.5 - 4.0 mm: 80 μm (0.0031"); ø 4.5 - 5.0 mm: 120 μm (0.0047")
Stent material Cobalt chromium (L-605) with proBIO (Amorphous Silicon Carbide) coating
Maximum stent expansion diameter ø 2.5 - 3.0 mm: 3.50 mm; ø 3.5 - 4.0 mm: 4.65 mm; ø 4.5 - 5.0 mm: 5.63 mm
Delivery system
Guide wire diameter 0.014"
Usable catheter length 140 cm
Recommended guide catheter ø 2.5 - 4.0 mm: 5F (min. I.D.** 0.056"); ø 4.5 - 5.0 mm: 6F (min. I.D.** 0.070")
Nominal pressure (NP) ø 2.5 - 3.5 mm: 8 atm; ø 4.0 - 5.0 mm: 7 atm
Rated burst pressure (RBP) ø 2.5 - 4.0 mm: 16 atm; ø 4.5 - 5.0 mm: 14 atm
  **I.D. = Inner Diameter

Ordering Information

2.5 (5F) 369380 369386 -
3.0 (5F) 369381 369387 381789
3.5 (5F) 369382 369388 381790
4.0 (5F) 369383 369389 381791
4.5 (6F) 369384 369390 369392
5.0 (6F) 369385 369391 369393

Contact

contact
Country/Region

1. Compared to Graftmaster Coronary Stent Graft System 2.8/16 (BIOTRONIK data on file, based on specifications);

2. Compared to Graftmaster Coronary Stent Graft System 2.8/16 (BIOTRONIK data on file, IIB data 2020)

3. Hernandez-Enriquez M, Lairez O, Campelo-Parada F, et al. Outcomes after use of covered stents to treat coronary artery perforations. Comparison of old and new-generation covered stents. J Interv Cardiol. 2018;1–7. doi: 10.1111/joic.12525

4. Population is representative of real world interventional practice and was not a randomized prospective clinical trial.

PK Papyrus and proBIO are trademarks or registered trademarks of the BIOTRONIK Group of Companies. Jostent and Graftmaster are trademarks or registered trademarks of the Abbott Group of Companies.

*Indication as per IFU.