Therapy

Therapy*

Ablation Catheters and Devices

Image
BIOTRONIK Ablation Therapy Ablation Catheter AlCath Flux G eXtra
Image
BIOTRONIK Ablation Therapy RF Generator Qubic RF
Image
Qiona
Image
BIOTRONIK Ablation Therapy Ablation Catheter AlCath G FullCircle
Image
BIOTRONIK Contact Force Ablation Force Sensing Unit Qubic Force Impulse
Image
AlCath Force Contact Force Ablation
Image
BIOTRONIK Contact Force Ablation Force Sensing Unit Qubic Force and Monitor
Image
BIOTRONIK Contact Force Ablation AlCath Force Catheter
Image
BIOTRONIK Ablation Therapy Ablation Catheter AlCath Flux G eXtra
Image
BIOTRONIK Ablation Therapy RF Generator Qubic RF
Image
Qiona
Image
BIOTRONIK Ablation Therapy Ablation Catheter AlCath G FullCircle
Image
BIOTRONIK Contact Force Ablation Force Sensing Unit Qubic Force Impulse
Image
AlCath Force Contact Force Ablation
Image
BIOTRONIK Contact Force Ablation Force Sensing Unit Qubic Force and Monitor
Image
BIOTRONIK Contact Force Ablation AlCath Force Catheter

Ablation Therapy

Our technologies enable physicians to provide highly effective therapies to patients suffering from cardiovascular and endovascular diseases. In the field of electrophysiology, BIOTRONIK offers state-of-the-art solutions that diagnose and treat patients with cardiac arrhythmias.

Ablation Catheters and Devices

With our AlCath ablation catheter family, BIOTRONIK offers a broad range of steerable, bidirectional irrigated and non-irrigated products. Our unique GoldTip maximizes the natural cooling effect of the blood for safe and effective lesion creation, especially with non-irrigated catheter variants. With its long tip or irrigated catheter, the AlCath Flutter represents the gold standard for treating Atrial Flutter, using its precise, stable positioning and full-circle deflection. Find out more about our outstanding range of ablation products.
Qubic RF ablation generator and the corresponding irrigation pump Qiona are the optimal addition for ablating any atrial arrhythmia with AutoFlow functionality.

Contact Force Ablation

BIOTRONIK's Contact Force Ablation portfolio enables atrial fibrillation ablation procedures with significantly improved outcomes. The real-time feedback of the force application between the catheter tip and the myocardium is only one of many features providing the advantages of controlling contact force.

Ablation Catheters and Devices

Ablation Catheters

Contact Force Ablation

RF Generator

Irrigation Pump

Contact us

Ablation Catheters

Ablation Catheters

With our AlCath ablation catheter family, BIOTRONIK offers a broad range of steerable, bidirectional irrigated and non-irrigated products. Our unique GoldTip maximizes the natural cooling effect of the blood for safe and effective lesion creation, especially with non-irrigated catheter variants. With its long tip or irrigated catheter, the AlCath Flutter represents the gold standard for treating Atrial Flutter, using its precise, stable positioning and full-circle deflection. Find out more about our outstanding range of ablation products.

Image
BIOTRONIK Ablation Catheter Overview

Flutter RF Ablation Catheter

Designed specifically for treating atrial flutter, this 95cm-long catheter is optimized for ablating the tricuspid isthmus. High-density braiding and the gold tip's lateral stabilization ensure a stable position on the tricuspid isthmus during the whole ablation procedure, leading to a fast and effective result.

 

Find out more about our flutter RF ablation catheter.

Open all

AlCath Flutter Flux G eXtra

3.5 mm irrigated GoldTip Ablation catheter


Product details

  • Model: AlCath Flutter Flux Black G eXtra
  • Curve Type: Black
  • Electrode spacing: 2-5-2 mm
  • Effective catheter length: 95 cm 
  • Shaft diameter: 7 F
  • Curve shape: Steerable - FullCircle
Icon Irrigated GoldTip Ablation

Irrigated GoldTip ablation

GoldTip ablation results in superior acute efficacy and shorter procedure times in treating atrial fibrillation

Product highlights

  • Reinforced stability - Lateral stabilization of AlCath Flutter tip segment for effective tip-to-tissue contact
  • Reduced Length - AlCath Flutter handling design optimized for right atrial ablations

Image
BIOTRONIK Ablation Therapy AlCath Flutter Flux G eXtra 3.5 mm Irrigated GoldTip Ablation Catheter

AlCath Flutter LT G

8 mm GoldTip Ablation catheter


Product details

  • Model: AlCath Flutter Black LT G
  • Curve Type: Black
  • Electrode spacing: 2-5-2 mm
  • Effective catheter length: 95 cm 
  • Shaft diameter: 7 F
  • Curve shape: Steerable - FullCircle
  • Tip electrode type: Non-irrigated
Icon LT GoldTip Ablation

LT GoldTip Ablation

LT GoldTip has a higher acute ablation success rate, with reduced coagulation during atrial flutter procedures, when compared to conventional catheters

Product highlights

  • Reinforced Stability
    Lateral stabilization of AlCath Flutter tip segment for effective tip-to-tissue contact
  • Reduced Length
    AlCath Flutter handling design optimized for right atrial ablations

Image
AlCath Flutter LT G 8 mm GoldTip Ablation Catheter

Irrigated RF Ablation catheter

The AlCath Flux eXtra irrigated ablation catheters have a unique gold or platinum iridium tip, FullCircle (270°) deflection, and a three-dimensional cooling pattern, providing more effective therapy for supraventricular tachycardias.

 

Find out more about our irrigated RF ablation catheter.

Open all

AlCath Flux G eXtra

3.5 mm irrigated GoldTip Ablation catheter


Product details

  • Curve Type: Red, blue, green, black, cyan
  • Electrode spacing: 2-5-2 mm
  • Effective catheter length: 110 cm 
  • Shaft diameter: 7 F
  • Curve shape: Steerable - FullCircle
  • Tip electrode type: Irrigated
Icon Irrigated GoldTip Ablation

Irrigated GoldTip ablation

GoldTip ablation results in superior acute efficacy and shorter procedure times in treating atrial fibrillation

Product highlights

  • eXtra Design - 12 irrigation holes on 3 levels arranged with a 3D irrigation pattern
  • FullCircle deflection - Deflectability beyond 180 degrees through FullCircle deflection

Image
AlCath Flux G eXtra 3.5 mm Irrigated GoldTip Ablation Catheter

AlCath Flux eXtra

3.5 mm irrigated tip Ablation catheter


Product details

  • Curve Type: Red, blue, green, black, cyan
  • Electrode spacing: 2-5-2 mm
  • Effective catheter length: 110 cm 
  • Shaft diameter: 7 F
  • Curve shape: Steerable - FullCircle
  • Tip electrode type: Irrigated
  • Electrode material: Platinum Iridium (Pt/Ir)
Icon eXtra Design

eXtra Design

12 irrigation holes on 3 levels arranged with a 3D irrigation pattern

 

Product highlights

  • FullCircle deflection - Deflectability beyond 180 degrees through FullCircle deflection
  • Handling - Precise positioning through push-pull steering incl. AutoLock

Image
AlCath Flux eXtra 3.5 mm Irrigated Tip Ablation Catheter

Non-Irrigated RF Ablation Catheter

The AlCath G FullCircle series of ablation catheters are available in different electrode tip lengths, curve sizes and FullCircle 270° deflection. They ensure effective and safe ablation of various cardiac arrhythmias.

 

Find out more about our non-irrigated RF Ablation catheter.

Open all

AlCath LT G FullCircle

8 mm GoldTip Ablation catheter


​Product details

  • Curve Type: Red, blue, green, black, cyan
  • Electrode spacing: 2-5-2 mm
  • Effective catheter length: 110 cm 
  • Shaft diameter: 7 F
  • Curve shape: Steerable - FullCircle
  • Tip electrode type: Non-irrigated
  • Electrode material: Gold (Au)
Icon LT GoldTip Ablation

LT GoldTip Ablation

LT GoldTip has a higher acute ablation success rate and reduced coagulum formation for atrial flutter compared to conventional catheters

Product highlights

  • FullCircle deflection - Deflectability beyond 180 degrees through FullCircle deflection
  • Handling - Precise positioning through push-pull steering incl. AutoLock

Image
AlCath LT G FullCircle 8 mm GoldTip Ablation Catheter

AlCath G FullCircle

4 mm GoldTip Ablation catheter


Product details

  • Curve Type: Red, blue, green, black, cyan
  • Electrode spacing: 2-5-2 mm
  • Effective catheter length: 110 cm 
  • Shaft diameter: 7 F
  • Curve shape: Steerable - FullCircle
  • Tip electrode type: Non-irrigated
  • Electrode material: Gold (Au)
Icon GoldTipAblation

GoldTip Ablation

GoldTip Ablation results in 33% faster lesions compared to conventional catheters

 

Product highlights

  • FullCircle deflection - Deflectability beyond 180 degrees through FullCircle deflection
  • Handling - Precise positioning through push-pull steering incl. AutoLock

Image
AlCath G FullCircle 4 mm GoldTip Ablation Catheter

AlCath LT FullCircle

8 mm tip Ablation catheter


Product details

  • Curve Type: Red, blue, green, black, cyan
  • Electrode spacing: 2-5-2 mm
  • Effective catheter length: 110 cm 
  • Shaft diameter: 7 F
  • Curve shape: Steerable - FullCircle
  • Tip electrode type: Non-irrigated
  • Electrode material: Platinum Iridium (Pt/Ir)
  • Tip electrode length: 8mm

Product highlights

  • FullCircle deflection - Deflectability beyond 180 degrees through FullCircle deflection
  • Handling - Precise positioning through push-pull steering incl. AutoLock

Image
AlCath LT FullCircle 8 mm Tip Ablation Catheter

AlCath FullCircle

4 mm Tip Ablation Catheter


Product details

  • Curve Type: Red, blue, green, black, cyan
  • Electrode spacing: 2-5-2 mm
  • Effective catheter length: 110 cm 
  • Shaft diameter: 7 F
  • Curve shape: Steerable - FullCircle
  • Tip electrode type: Non-irrigated
  • Electrode material: Platinum Iridium (Pt/Ir)
  • Tip electrode length: 4 mm

Product highlights

  • FullCircle deflection - Deflectability beyond 180 degrees through FullCircle deflection
  • Handling - Precise positioning through push-pull steering incl. AutoLock

Image
AlCath FullCircle 4 mm Tip Ablation Catheter
Contact Force Ablation

Contact Force Ablation

Contact Force Ablation BIOTRONIK's Contact Force Ablation portfolio enables atrial fibrillation ablation procedures with significantly improved outcomes. The real-time feedback of the force application between the catheter tip and the myocardium is only one of many features providing the advantages of controlling contact force.

The AlCath Force is a steerable, irrigated, quadripolar catheter with an integrated force sensor. The advanced single optical fiber technology allows for three-dimensional force measurement. It is built on the well-established AlCath Flux eXtra Gold catheter with X-shaped irrigated GoldTip electrodes, maximizing the natural cooling effect of the blood for safe and effective lesion creation at low flow rates. The Force Sensing Unit Qubic Force allows physicians to visualize the AlCath Force catheter tip's contact force on the cardiac wall during an electrophysiological procedure, with or without radiofrequency ablation delivery.
Open all

AlCath Force

Contact Force Catheter


AlCath Force

AlCath Force is a steerable, irrigated, quadripolar catheter with an integrated force sensor. It is built on the well-established AlCath Flux eXtra Gold catheter with X-shaped irrigated GoldTip electrodes, maximizing the natural cooling effect of the blood for safe and effective lesion creation at low flow rates. The advanced single optical fiber technology allows for three-dimensional force measurement. It is built on the well-established AlCath Flux eXtra Gold catheter with X-shaped irrigated GoldTip electrodes, maximizing the natural cooling effect of the blood for safe and effective lesion creation at low flow rates.

 

Product details

  • Curve types: red, blue, green black, cyan
  • Tip electrode length: 3.5 mm
  • Tip electrody type: Irrigated, 12 holes
  • Electrode spacing: 2-5-2 mm 
  • Electrode material: Gold (Au)
  • Shaft diameter: 8F 
  • Curve shape: Steerable - FullCircle
  • Length: 110 cm
BIOTRONIK Contact Force Ablation AlCath Force Catheter

Icon Effective Lesions

Effective lesions

BIOTRONIK’s unique GoldTip, together with its proven three dimensional x-shaped irrigation, delivers effective lesions.

Icon Lower irrigation flow / volume

Lower irrigation flow / volume

Innovative force sensing GoldTip with 3D irrigation holes enables uniform cooling and reduced flow rates


Image
BIOTRONIK Contact Force Ablation AlCath Force Catheter

Stable force measurement

  • Dedicated temperature sensor reduces temperature-induced false force readings.
  • Isolated force sensor measures contact force applied at the ablation tip, and is not affected by curve deflection.

Image
BIOTRONIK Contact Force Ablation AlCath Force Catheter

Qubic Force

Force Sensing Unit


Qubic Force

The Force Sensing Unit Qubic Force allows physicians to visualize the AlCath Force catheter tip's contact force on the cardiac wall during an electrophysiological procedure, with or without radiofrequency ablation delivery.

An external monitor is placed in a position easily visible to the user and connected to the Qubic Force. The contact force is displayed which allows the user to monitor the contact force ofthe ablation catheter tip on the cardiac wall, establish proper contacton the cardiac wall, and influence lesion formation.

 

Product highlights

  • Clear structure and focus on the essentials - absolute force, catheter angulation, force history
BIOTRONIK Contact Force Ablation Force Sensing Unit Qubic Force and Monitor

Icon Plug and Play

Plug-and-Play connection to AlCath Force

  • Easy to understand user interface without additional interaction
  • Connection do HDMI monitors
  • Qubic Family allows for optimal lab integration 
Icon Intuitive 2D representation of 3D information

Intuitive 2D representation of 3D information

  • Catheter contact in relation to tissue (0° to 90°)
  • Peripheral identification of exceeding forces through color changes

Image
BIOTRONIK Contact Force Ablation Force Sensing Unit Qubic Force

Image
BIOTRONIK Contact Force Ablation Force Sensing Unit Qubic Force Impulse

AcQMap System with Contact Force Integration

Individual contact force ablation therapy with AcQMap

The seamless integration of AlCath Force, Qubic Force and Qubic RF enables a complete and customized visualization of contact force information as well as RF generator parameters displayed directly into the system's interface.

Find out more about the AcMap System with contact force integration. 

BIOTRONIK AcQMap System with Contact Force Integration
RF Generator

Qubic RF

The Qubic RF is a modular radiofrequency generator that allows any current electrophysiological treatments for cardiac radiofrequency ablation. It has one of the smallest footprints in the market, is easy to set up and pairs perfectly with the Qiona irrigation pump for ease of use during procedures.

 

Product highlights

  • Simple user interface
    Qubic RF's complete functionality is displayed in 4 menu screens
  • 5-click-go 
    Once the catheter is connected, ablation can be started in five click
BIOTRONIK Ablation Therapy RF Generator Qubic RF
Icons Adaptive High Flow

Adaptive high flow

3 High Flow levels following adaptable power thresholds


AcQMap System with Contact Force Integration

Individual contact force ablation therapy with AcQMap

The seamless integration of AlCath Force, Qubic Force and Qubic RF enables a complete and customized visualization of contact force information as well as RF generator parameters displayed directly into the system's interface.

Find out more about the AcMap System with contact force integration. 

BIOTRONIK AcQMap System with Contact Force Integration

Image
BIOTRONIK Ablation Therapy RF Generator Qubic RF Technical
Image
BIOTRONIK Ablation Therapy RF Generator Qubic RF
Image
BIOTRONIK Ablation Therapy Qubic RF
Image
BIOTRONIK Ablation Therapy Qubic RF

Irrigation Pump

Qiona

The Qiona irrigation pump is the perfect addition to the ablation setup. It features adjustable low flow and high flow functions, preventing coagulation and blockage of the catheter opening. This helps enable the catheter tip to cool.
Together with the Qubic RF ablation generator, Qiona is the optimal addition for ablating any atrial arrhythmia, with the Qubic RF seamlessly remote controlling and remotely configuring the Qiona. It's easy to use during complex EP procedures.

BIOTRONIK Ablation Therapy Irrigation Pump Qiona
Icon Freedom of Choice

Freedom of choice

  • Remote control using Qubic RF (via VK-119)
  • Compatibility with all common RF generators via AutoFlow sensor

Product highlights

Ease of use

  • Ready to flush in just two steps
  • One-swing tube feeding and adjustment

Ease of mind

  • Bottle depletion control and alarm allow reservoir changes in time
  • Tube pressure monitor and alarm provide warnings regarding blocked irrigation lumens

Image
BIOTRONIK Ablation Therapy Irrigation Pump Qiona

Contact us
contact
Country/Region

*product availability depends on local regulatory approval. Please contact your BIOTRONIK representative to check for availability.