DX

Afbeelding
Single chamber ICD system with complete atrial diagnostics
DX Technology
Afbeelding
DX lead
DX Lead
Afbeelding
Single chamber ICD system with complete atrial diagnostics
DX Technology
Afbeelding
DX Lead, dipole rings
DX Lead, dipole rings
Afbeelding
Single chamber ICD system with complete atrial diagnostics
DX Technology
Afbeelding
DX lead
DX Lead
Afbeelding
Single chamber ICD system with complete atrial diagnostics
DX Technology
Afbeelding
DX Lead, dipole rings
DX Lead, dipole rings

DX Technology

Protecting Single-Chamber ICD Patients from Undetected AF

DX technology is a pioneering solution developed to increase therapy effectiveness and improve patients' quality of life. The DX system offers complete atrial diagnostics in a single lead ICD device, thereby encompassing the benefits of both single and dual-chamber ICDs. Signals coming from the atrial chambers of a patient’s heart can now be sensed by the floating dipole rings located in the proximal part of the DX lead, thanks to a special atrial input stage of the DX device.12 Detection of asymptomatic atrial fibrillation (AF) together with the early notification BIOTRONIK Home Monitoring® provides, enables timely intervention for AF management, reducing the risk of further complications and related hospitalization.34 Atrial sensing allows the SMART Detection algorithm to discriminate supraventricular tachycardias (SVTs) from ventricular tachycardias (VTs) by analyzing atrial and ventricular rhythms, an exclusive feature previously available only in dual-chamber ICDs.5 High sensitivity and specificity on SVT/VT discrimination contributes to safely reduce the risk of inappropriate shocks. The MATRIX study, an ongoing international, multicenter, observational registry, will evaluate the impact of the enhanced features and capabilities of the new BIOTRONIK DX system on detection and management of AF in an unselected real-world setting.6 The BIOTRONIK DX System provides unique protection to ICD patients who do not require atrial pacing.



DX System Clinical Benefits

DX System Clinical Benefits

  • Detection of asymptomatic AF episodes
  • Optimized AF management
  • Enhanced arrhythmia diagnosis
  • Safe shock reduction
  • Heart failure monitor
DX System Highlights

DX System Highlights

  • 3-channel intracardiac electrogram (IEGM), including RA, RV and far-field
  • SMART Detection or MorphMatch, onset and stability
  • Complete AF and heart failure diagnostics
  • Ultra high-energy model available (45 J)
  • BIOTRONIK Home Monitoring
  • MR conditional7
Patient undergoes an MRI scan

ProMRI

ProMRI technology offers patients safe access to MRIs under certain conditions.

For details, visit

ProMRI microsite

Physician and nurse are looking at the patient status on the HMSC

Home Monitoring

BIOTRONIK Home Monitoring is a remote monitoring service available with cardiac monitors, pacemakers, implantable defibrillators (ICD) and cardiac resynchronization therapy (CRT) systems. Home Monitoring allows physicians to continuously and reliably survey their patients’ physiological and device condition and alerts responsible healthcare staff of acute health changes within 24 hours.


Media

Single chamber ICD system with complete atrial diagnostics


Studies

MATRIX Study

  • Management and Detection of Atrial Tachyarrhythmias in Patients Implanted With BIOTRONIK DX Systems
  • Single chamber Biotronik DX system with enhanced atrial diagnostics
  • Efficacy and safety of the single chamber Biotronik DX
MATRIX Study
contact
Country/Region

1 Safak E et al. Clinical efficacy and safety of an implantable cardioverter-defibrillator lead with a floating atrial sensing dipole. Pacing Clin Electrophysiol. 2013; 36: 952-62.

3 Mabo P et al. A Randomized Trial of Long-Term Remote Monitoring of Pacemaker Recipients (The COMPAS Trial). European Heart Journal. 2012; 33: 1105 –11.

5 Sinha et al. Discrimination of VT and SVTs with a new detection algorithm in a dual-chamber ICD. Herzschrittmacher. 2000; 20(3): 208-14.

7 Regulatory approval may differ per region

2 Iori M et al. Implantable cardioverter defibrillator system with floating atrial sensing dipole: a single-center experience. Pacing Clin Electrophysiol. 2014; 37(10):1265-73.

4 Guédon-Moreau L et al., Decreased delivery of inappropriate shocks achieved by remote monitoring of ICD: A sub-study of the ECOST trial. J Cardiovasc Electrophysiol. 2014; 25(7): 763 – 70.

6 Management and detection of Atrial TachyaRrhythmias in patients Implanted with BIOTRONIK DX systems (MATRIX). www.clinicaltrials.gov Study-Identifier: NCT01774357

8 Feature availability is device model-specific. See manual specifications for more details.