Indicated for femoral and proximal popliteal arteries. Being a relatively mobile artery, the Superficial Femoral Artery (SFA) requires a stent that conforms to the natural vessel movement and provides sufficient support in complex, long lesions that are often difficult to cross. Pulsar-35 is a stent designed for SFA with high multi-directional flexibility on a tri-axial delivery system.


KEY FACTS
  • One-handed stent release for accurate stent deployment
  • Tri-axial shaft for a stable delivery system during stent deployment
  • S-articulating connecting bars and peak-to-valley design for multi-directional flexibility
  • Segmented stent design with thin struts for lower restenosis rates

Product Details

Pulsar-35 image

Tri-Axial OuterShaft

Isolates retractable shaft from friction caused by introducer valve, aimed at ensuring precision-like implantation accuracy.


    Pulsar-35 image

    Stent Designed for SFA

    • Peak-to-valley design and S-articulating connecting bars provide multi-directional flexibility and avoid fish-scaling in mobile vessel architecture.
    • A segmented design with thin struts provides low Chronic Outward Force (COF)1 sufficient to maintain vessel scaffolding even in calcified lesions (4EVER study)2. High COF has been shown to result in higher rates of neointimal hyperplasia.3
    • Stent lengths up to 200 mm for covering long lesions with a single stent.

    Pulsar-35 image

    One-Handed Stent Release

    Ergonomically designed for a comfortable and stable handling, enhancing ability to immobilize complete system during stent deployment.

    • Safety tab: Avoids accidential stent deployment
    • Trigger: For controlled stent delivery

    Low Chronic Outward Force

    Low Chronic Outward Force (COF)1 sufficient to maintain vessel scaffolding even in calcified lesions (4EVER study2). COF of Pulsar stents increases less than many competitor stents when oversized, thus potentially reducing inflammatory response and restenosis3.



      Technical Data

      Pulsar-35 Stent
      Catheter type
      OTW
      Recommended guide wire
      0.035"
      Stent material
      Nitinol
      Strut thickness
      140 μm
      Strut width
      85 μm
      Stent coating
      proBIO (amorphous silicon carbide)
      Stent markers
      6 gold markers each end
      Sizes
      ø 5.0 - 7.0 mm; L: 30 - 200 mm
      Proximal shaft
      6 F, hydrophobic coating
      Usable length
      90 and 135 cm

      Ordering Information


      Contact

      contact
      Country/Region

      1 BIOTRONIK data on file (IIB report (P) 71/2011-1).

      2 4EVER study. Bosiers. M. 24m results presented CIRSE 2013; Deloose K. 24m results presented LINC 2014.

      3 -Ballyk PD. Intramural stress increases exponentially with stent diameter: a stress threshold for neointimal hyperplasia. J Vasc Interv Radiol. 2006 Jul;17(7):1139-45. -Freeman JW, Snowhill PB, Nosher JL. A link between stent radial forces and vascular wall remodeling: the discovery of an optimal stent radial force for minimal vessel restenosis. Connect Tissue Res. 2010 Aug;51(4):314-26. -Zhao HQ, Nikanorov A, Virmani R, Jones R, Pacheco E, Schwartz LB. Late stent expansion and neointimal proliferation of oversized Nitinol stents in peripheral arteries. Cardiovasc Intervent Radiol. 2009 Jul;32(4):720-6".