Dynamic Renal

Afbeelding
Image of Dynamic Renal
Dynamic Renal Balloon-Expandable Cobalt Chromium Stent
Afbeelding
Image of Dynamic Renal
Dynamic Renal Balloon-Expandable Cobalt Chromium Stent
Afbeelding
Image of Dynamic Renal
Dynamic Renal Balloon-Expandable Cobalt Chromium Stent
Afbeelding
Image of Dynamic Renal
Dynamic Renal Balloon-Expandable Cobalt Chromium Stent

Dynamic Renal

BALLOON-EXPANDABLE COBALT CHROMIUM STENT

Indicated for renal arteries. A stent specifically designed for renal arteries, combining excellent stent and balloon technologies.


KEY FACTS
  • Proximal gold marker for superior visibility and accurate stent placement
  • Double helix stent design for high flexibility
  • Cobalt chromium alloy combining a lower profile with improved radial force
  • proBIO coating for improved stent surface biocompatibility1

Product Details

Superior Visibility Enhances Placement Accuracy

A gold plated radiopaque marker ring at the proximal stent end, combined with a cobalt chromium alloy, facilitates superior visibility and accurate ostial stent placement. Furthermore, minimal stent shortening characteristics ensure predictable deployed stent length for additional lesion coverage accuracy.


    Dynamic Renal image

    Increased Stent Flexibility

    The double helix stent design ensures high flexibility, homogenous wall coverage and superb conformability.


      Lower Crossing Profile and Increased Scaffolding

      The cobalt chromium alloy permits thinner struts, which result in a lower crossing profile. Thus, deliverability is improved while the radial force supporting the vessel scaffolding is increased at the same time.


        proBIO Silicon Carbide Coating

        proBIO acts as a diffusion barrier, sealing the bare metal surface and reducing ion release. In vitro studies have shown up to a 96% reduction of allergenic metal ions2 when the stent surface is coated with silicon carbide. By providing a barrier against ion release, the silicon carbide coating creates a surface that reduces platelet aggregation while facilitating endothelialization.1


          Dynamic Renal image

          Exceptional Delivery Performance

          The stent delivery system combines advanced thermal crimping techniques, ensuring secure stent retention forces and a smooth, low crossing profile. The short balloon overhang can prevent barotrauma on healthy vessels and the laser cut, short balloon tip provides excellent crossability and improved trackability.


            Technical Data

            Dynamic Renal Stent
            Stent
            Balloon-expandable
            Stent material
            Cobalt chromium (L605)
            Strut thickness
            120 μm (ø 4.5 - 5.0 mm)
            140 μm (ø 6.0 - 7.0 mm)
            Stent coating
            proBIO (amorphous silicon carbide)
            Stent marker
            Proximal gold marker
            Sizes
            ø 4.5 - 7.0 mm; L: 12 - 19 mm
            Delivery system
            Catheter type Rapid exchange (Rx)
            Recommended guide wire 0.014"
            Tip Soft, short and tapered
            Balloon markers 2 swaged markers
            Shaft (proximal) Hydrophobic coating
            Usable length
            140 cm
            Nominal pressure (NP)10 atm
            Rated burst pressure (RBP) 15 atm (ø 4.5 - 6.0 mm)
            13 atm (ø 7.0 mm)

            Compliance Chart

            Balloon Diameter x Length (mm)
            Nominal Pressureatm310101010
            NPø (mm)4.55.06.07.0
            Rated Burst Pressureatm315151513
            RBPø (mm)4.75.36.27.2

            Ordering Information


            Contact

            contact
            Country/Region

            1 Rzany A, Schaldach M. 2001. Progress in Biomedical Research 2001 May: 182-194.

            2 BIOTRONIK data on file.

            3 1 atm = 1.013 bar