Passeo-35

Afbeelding
Passeo-35 balloon
Passeo-35 PTA Balloon
Afbeelding
Passeo-35 balloon
Passeo-35 PTA Balloon
Afbeelding
Passeo-35 balloon
Passeo-35 PTA Balloon
Afbeelding
Passeo-35 balloon
Passeo-35 PTA Balloon

Passeo-35

PTA BALLOON

Indicated for lower limb, renal1 and iliac arteries1. Treatment of arterio-venous dialysis fistulae. Passeo-35 features a low profile design for 5 F and 6 F Sheath compatibility, a wide range of balloon diameters (3 - 10 mm) and lengths of up to 200 mm. Above all, with its puncture resistant balloon material, Passeo-35 competes in most calcified lesions.


KEY FACTS
  • Low profile, wide range: ø 3 - 10 mm and up to 200 mm balloon length
  • Puncture resistant balloon material for most calcified lesions
  • 5 F shaft for uncompromised flush capability and angiographic quality
  • Patchwork coating for enhanced crossability

Product Details

Low Profile and Wide Range – As Best in Class

A comprehensive choice of 5 F and 6 F configurations.


    Puncture Resistant Balloon Material

    A robustly engineered balloon that provides effective dilation; suitable for most calcified lesions.


      Passeo-35

      Patchwork Coating for Enhanced Crossability

      The penta-fold balloon is fully coated when folded and only partly coated when inflated. This enables enhanced crossability while minimizing slippage during the inflation of most calcified lesions.


        Shaft Design

        5 F shaft for uncompromised flush capability and angiographic quality.


          Technical Data

          Balloon Catheter
          Catheter type OTW
          Recommended guide wire 0.035"
          Tip Soft, short, tapered, colored
          Balloon material SCP (semi-crystalline polymer), controlled compliance
          Balloon folding 5-fold
          Balloon coating Hydrophobic patchwork coating
          Balloon markers 2 swaged markers
          Sizes ø 3.0 - 10.0 mm; L: 20 - 200 mm
          Shaft 5 F, hydrophobic coating, dual-lumen
          Usable length 80, 90 and 130 cm
          Guide wire lumen Hydrophobic coating

          Compliance Chart

          Balloon Diameter x Length (mm)
          Nominal Pressureatm277777777777777
          (NP)ø (mm)3.03.04.04.05.05.06.06.07.07.08.09.010.010.0
          Rated Burst Pressureatm22020201816161616141414121211
          (RBP)ø (mm)3.53.24.54.325.75.36.76.47.77.38.79.410.510.3

          Ordering Information


          contact
          Country/Region

          1 Australia: not TGA approved for use within the renal and common iliac arteries.

          2 Usable length: 80 cm

          3 1 atm = 1.013 bar

          4 8 weeks pre-order only