Passeo-18 Lux

Obraz
Image of Passeo-18 Lux
Passeo-18 Lux Drug-Coated Balloon
Obraz
Image of Passeo-18 Lux
Passeo-18 Lux Drug-Coated Balloon
Obraz
Image of Passeo-18 Lux
Passeo-18 Lux Drug-Coated Balloon
Obraz
Image of Passeo-18 Lux
Passeo-18 Lux Drug-Coated Balloon

Passeo-18 Lux

DRUG-COATED BALLOON

Indicated for lower limb arteries. The Passeo-18 Lux drug-coated balloon - an advanced therapy to expand conventional PAD treatment options - proven to inhibit restenosis while maintaining a high safety profile.


KEY FACTS
  • Clinically proven to reduce restenosis and the need for reinterventions1
  • Lux coating technology optimizes drug transfer for maximized efficacy
  • Low profile, highly deliverable Passeo-18 balloon platform
  • Innovative SafeGuard insertion aid for unrivaled safety and ease of handling

Product Details

Safe and Effective

Robust, high-quality clinical data demonstrate Passeo-18 Lux safety and efficacy in the treatment of femoropopliteal and infrapopliteal arteries.


    Passeo-18 Lux image

    BIOLUX P-I2,3 Femoropopliteal Indication

    6-month Binary Restenosis:
    Passeo-18 Lux significantly reduced Binary Restenosis compared to the control PTA balloon (p = 0.048*).

    *p < 0.05 is significant


      Passeo-18 Lux image

      12-month Target Lesion Revascularization4:
      Passeo-18 Lux significantly reduced Target Lesion Revascularization rates compared to the control PTA balloon (p = 0.020*).

      *p < 0.05 is significant


        Passeo-18 Lux image

        BIOLUX P-II3, 5 Infrapopliteal Indication

        6-month change in Rutherford Class:
        Passeo-18 Lux improved Rutherford Class compared to the control PTA balloon.


          Passeo-18 Lux image

          12-month Major Amputation:
          Passeo-18 Lux Major Amputation rate was lower compared to the control PTA balloon. In the DCB group, it was 3.3 % at 6 months and no additional amputation occurred after 180 days.


            Optimized Coating Formulation

            The Lux coating technology provides an optimal delivery mechanism, ensuring minimal drug loss during tracking and inflation, rapid drug transfer to the vessel wall and a sustained therapeutic effect.6

            • Drug: 3 μg/mm2 paclitaxel anti-proliferative agent
            • Excipient: butyryl-tri-hexyl citrate (BTHC) hydrophobic carrier improves coating integrity so that more drug is available at the lesion site. Safe and biocompatible.
            • Coating process: homogeneous balloon coating shelters drug within the balloon folds and ensures drug transfer to the entire region treated.

            Low Profile Delivery Platform

            Passeo-18 Lux is part of BIOTRONIK 4F solutions. It is based on the Passeo-18 low profile balloon platform, thus minimizing the risk of access site complications7 and improving lesion crossing performance.


              SafeGuard – Improved and Safer Handling

              SafeGuard insertion aid improves ease of handling and protects the user and balloon coating from contact and damage. It is pre-mounted on the balloon and after use, it can simply be peeled away.


                Media

                Passeo-18 Lux

                This video demonstrates how the clinically-proven Passeo-18 Lux treats de novo and restenotic lesions in the infrainguinal arteries.


                BIOLUX P-I

                • Prospective, multi-center, 1:1 randomized, controlled trial enrolling 60 patients at five clinical sites in Germany and Austria.
                • Number of patients (n): 60
                • Primary endpoint: 6-month LLL in target lesion measured by quantitative vascular angiography (QVA) by an independent corelab

                BIOLUX P-II

                • Prospective, multi-center, randomized controlled, first-in-human study
                • Number of patients (n): 72
                • Primary endpoint: 30-day MAE rate2, 6-month TLP measured by quantitative vascular angiography (QVA)

                DEBAS

                • Prospective, multi-center, investigator-initiated registry to evaluate the implantation outcome of the Pulsar-18 stent followed by Passeo-18 Lux DCB in the femoropopliteal arteries.
                • Number of patients (n): 65 (12-month data available on n 51)
                • Primary endpoint: PP at 12 and 24 months, defined as a binary duplex ultrasound ratio PSVR <2.5 at the stented target lesion with no clinically-driven reintervention within the stented segment.

                Technical Data

                Passeo-18 Lux
                Catheter type
                OTW
                Recommended guide wire
                0.018"
                Tip
                Short, tapered
                Balloon markers
                2 swaged markers (zero profile)
                Shaft
                3.8 F, hydrophobic coated
                Usable length
                90, 130 cm; 150 cm (only ø 2.0 mm)
                Introducer size
                4 F (ø 2.0 - 4.0 mm); 5F (ø 5.0 - 7.0 mm)
                Nominal Pressure (NP)
                6 atm
                Rated Burst Pressure (RBP)
                15 atm (ø 2.0 - 5.0 mm); 12 atm (ø 6.0 - 7.0 mm)
                Drug Coating
                Paclitaxel
                Drug concentration
                3.0 μg/mm2
                Coating matrix
                Paclitaxel and butyryl-tri-hexyl citrate (BTHC)
                Coated area
                Cylindrical section of the balloon, exceeding the proximal and distal markers

                Compliance Chart

                Balloon Diameter x Length (mm)
                Nominal Pressureatm86666666
                (NP)ø (mm)2.02.53.04.05.06.07.0
                Rated Burst Pressureatm815151515151212
                (RBP)ø (mm)2.12.63.34.35.26.37.2

                Ordering Information


                Contact

                contact
                Country/Region

                1 BIOLUX P-I and BIOLUX P-II Randomized Clinical Trials

                2 Scheinert D, et al. BIOLUX P-I. JEVT. 2015; 22(1): 14-21.

                3 Selected endpoints

                4 As-Treated population

                5 Zeller et al. BIOLUX P-II. J Am Coll Cardiol Intv. 2015; 8: 1614-22.

                6 Pre-clinical data on file at BIOTRONIK AG

                7 Bosiers M, et al. 4-French–Compatible Endovascular Material Is Safe and Effective in the Treatment of Femoropopliteal Occlusive Disease. Results of the 4EVER Trial. J Endovasc Ther. 2013; 20(6): 746-756.

                8 1 atm = 1.013 bar

                The Passeo®-18 Lux® DCB with its Lux® coating is part of the Lux® family of Paclitaxel-coated balloons from BIOTRONIK.