Skip to main content
  • Image

Passeo®-14

A FAST DEFLATING PTA Balloon to treat long complex lower limb lesions

Indicated for balloon dilatation of the stenotic portion of a lower limb artery for the purpose of improving perfusion.*

Category

Vascular Intervention Peripheral PVI Balloon Catheters

Product Highlights

Image

Up to 3.8 x faster deflation times¹

Image

Enhanced crossability

Image

High pushability and flexibility²

Up to 3.8 x faster deflation times¹

The coaxial catheter shaft design that creates a large balloon lumen facilitating rapid inflation and deflation.

Passeo-14 balloon deflates

  • 3.8 x faster than Amphirion Deep
  • 2.0 x faster than Coyote
  • 2.4 x faster than NanoCross
Image

The only forefront solution offering dedicated below the ankle sizes

  • ø 1.5 - 2.0 mm
  • 150 mm flexible distal shaft
  • Tailored stiffening wire

Enhanced crossability

The tri-fold balloon enables an enhanced crossability while minimizing slippage during inflation.

The balloon is fully coated with a hydrophilic coating when folded and only partly coated when inflated.

Image

High pushability and flexibility²

Different designs of the proximal and coaxial catheter shafts enable impressive pushability and high flexibility.

Impressive pushability due to catheter shaft design featuring a unique stiffening wire in the proximal shaft of the catheter, while enabling high flexibility due to a lower profile distal shaft in small, tortuous vessels.

Product Overview

Passeo-14

Image

Technical Data

Balloon catheter
Catheter type OTW
Recommended guide wire 0.014”
Tip Optimized entry profile and colored
Balloon material SCP (Semi-Crystalline Polymer), controlled compliance (4 - 6%)
Balloon folding 3-fold
Balloon coating Hydrophilic patchwork coating
Balloon markers 2 swaged markers (zero profile)
Sizes ø 1.5 - 4.0 mm; L: 20 - 220 mm
Distal shaft 3.1F, hydrophilic coating, coaxial design; 150 mm length (ø 1.5 /2.0 x 20 -
100 mm); 75 mm length (ø 2.0 x 140 - 220 mm and ø 2.5 - 4.0 mm)
Proximal shaft 3.9F, hydrophobic coating, coaxial design; stiffening wire
Usable length 150 cm (ø 1.5 - 4.0 mm); 120 cm (ø 1.5 - 2.0 mm); 90 cm (ø 2.5 - 4.0 mm)

Compliance Chart

    Balloon diameter x length (mm)
    ø 1.5 x 20-70 ø 2.0 x 40-220 ø 2.5 x 40-220 ø 3.0 x 40-220 ø 3.5 x 40-140 ø 4.0 x 40-140

Nominal Pressure [NP]

atm* 7 7 7 7 7 7
ø (mm) 1.5 2.0 2.5 3.0 3.5 4.0
Rated Burst Pressure [RBP] atm* 14 14 14 14 14 14
ø (mm) 1.57 2.08 2.61 3.18 3.63 4.16

Ordering Information

 

  Catheter cm
Length (mm)
Balloon
ø (mm)
Balloon Length (mm)
      20 40 70 100 140 180 220

4F

Antegrade Approach 

120 1.5 380271a 380277 380283 - - - -
120 2 - 380278 380284 380290 380296 380302 380308
90 2.5 - 380279 380285 380291 380297 380303 380309
90 3 - 380280 380286 380292 380298 380304 380310
90 3.5 - 380281a 380287a 380293a 380299a - -
90 4 - 380282 380288 380294 380300 - -
  Catheter cm
Length (mm)
Balloon
ø (mm)
Balloon
Length (mm)
      20 40 70 100 140 180 220

4F

Crossover Approach 

150 1.5 380313a 380319 380325 - - - -
150 2 - 380320 380326 380332 380338 380344 380350
150 2.5 - 380321 380327 380333 380339 380345 380351
150 3 - 380322 380328 380334 380340 380346 380352
150 3.5 - 380323a 380329a 380335a 380341a - -
150 4 - 380324 380330 380336 380342 - -
a8 weeks pre-order only

How can we help you?

I prefer to be contacted by
*Fields are mandatory.

References

*Indication as per IFU.

1. BIOTRONIK data on file. Volume adjustment: A 3mm x 120mm balloon contains 17% less contrast media volume than a 3mm x 140mm balloon. The measured deflation time of a 3mm x 140mm balloon was adjusted by 17 % to make a direct competitive comparison;  2. BIOTRONIK Data on file.

Passeo is a trademark or registered trademark of the BIOTRONIK Group of Companies. All other trademarks are the property of their respective owners.