Skip to main content
  • Image

Pantera®LEO

Non-Compliant High Pressure Balloon Catheter

Indicated for stent post-dilatation and dilatation of a coronary artery or bypass graft stenosis.a

Category

Vascular Intervention Coronary CVI-Balloon Catheters

Product Highlights

Image

Lowest compliance in classb avoiding dog-bone effect1

More controlled growth from NP to RBP than leading competitorsc1

Image

Precise dilatation1

Extra short balloon shoulders reduce longitudinal balloon growth1

Image

Enhanced crossability1

Patchwork coating for enhanced crossability1

Technical Data

Proximal shaft  
Design Hypotube design
Diameter 2.0F
Shaft markers 92 cm and 102 cm from tip
Coating Hydrophobic
Distal shaft
Guiding catheter 5F (min. I.D. 0.056”)
Guide wire diameter 0.014”
Lesion entry profile 0.018”
Usable length 145 cm
Distal shaft length 34 cm
Balloon material SCP (Semi Crystalline Polymer)
Balloon folding 3-fold
Balloon markers Platinum-Iridium
Coating Hydrophilic (end of balloon to guide wire exit port);
hydrophobic (balloon and tip)
Diameter 2.6F (ø 2.0 - 3.75 mm); 2.7F (ø 4.0 - 5.0 mm)

Compliance Chart

    Balloon diameter x length (mm)
    ø 2.00 x
8-30 
ø 2.25 x
8-30
ø 2.50 x
8-30 
ø 2.75 x
8-30 
ø 3.00 x
8-30 
ø 3.25 x
8-30 
 ø 3.50 x
 8-30
ø 3.75 x
8-30
ø 4.00 x
8-30
ø 4.50 x
8-30
ø 5.00 x
8-30
Nominal Pressure
(NP)
atm* 14 14 14 14 14 14 14 14 14 14 14
ø (mm) 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.50 5.00
Rated Burst Pressure
(RBP)
atm* 20 20 20 20 20 20 20 20 20 18 18
ø (mm) 2.05 2.32 2.57 2.83 3.09 3.35 3.61 3.89 4.12 4.56 5.07
*1 atm = 1.013 bar

 

Ordering Information

  Balloon
ø (mm)
Catheter length 145 cm
Balloon length (mm)
5F   8 12 15 20 30
2.00 366991 367002 367013 367024 367035
2.25 366992 367003 367014 367025 367036
2.50 366993 367004 367015 367026 367037
2.75 366994 367005 367016 367027 367038
3.00 366995 367006 367017 367028 367039
3.25 366996 367007 367018 367029 367040
3.50 366997 367008 367019 367030 367041
3.75 366998 367009 367020 367031 367042
4.00 366999 367010 367021 367032 367043
4.50 367000 367011 367022 367033 367044
5.00 367001 367012 367023 367034 367045

How can we help you?

I prefer to be contacted by
*Fields are mandatory.

References

a. Indication as per IFU; b. When compared to main competitors, compliance curves 3.0 mm balloons; c. NP-RBP growth for 3.0 diameters. Leading competitors have been selected based on the PTCA Balloon Catheter Revenue Market Shares US, 2016; (Source: Milennium Research Group Inc.). Latest NC balloons for each competitor.

1. BIOTRONIK Data on file.

Pantera is a trademark or registered trademark of the BIOTRONIK Group of Companies.