Skip to main content
  • Image

Carnelian® Support Catheter

Multiple solutions for lesion crossing

 A Support Microcatheter indicated for the exchange and support of guidewires into peripheral vasculature.*

Category

Vascular Intervention Peripheral PVI Accessories

Product Highlights

Image

Extensive device selection for a wide range of lesions

Image

Lowest profile solution for excellent crossability

Image

Braided multi-segment shaft allowing a balance of support and flexibility

Extensive device selection for a wide range of lesions

The Carnelian Support microcatheter portfolio provides five different models with segmented shaft and tip configurations designed to address the complexity of lesion crossing in peripheral interventions.1

Lowest profile² solution for excellent crossability and trackability

The low profile of 1.8F or 1.6F3 is designed to facilitate trackability  and navigation through tortuous anatomy. The flexible tip and the hydrophilic coating allow for advanced crossing techniques such as transcollateral retrograde approach.

Braided multi-segment shaft allowing a balance of support and flexibility

Great flexibility and enhanced guidewire control

 

The multi-segment shaft design consists of 7 to 10 segments (depending on the model) providing variable levels of support and flexibility along the shaft length.This design allows for a smooth transition from floppy (soft) distal tip to allow for trackability, to the stiffer proximal shaft to allow for
additional push.

Product Overview

Carnelian Support

Image

Technical Data

Support Microcatheter  
French size Proximal: 2.6F
Distal: 1.6 or 1.8F
Usable length 60, 70, 80, 90, 110, 135 and 150 cm
Shaft material Tungsten braided shaft, PTFE liner
Coating Hydrophilic, distal 40, 60, 80, 100 and 120 cm
Tip Straight with platinum marker
Recommended guide catheter 0.035”

Ordering Information

Ordering Information Guidewire Usable length
(cm)
Distal
(F)
Proximal
(F)
Hydrophilic
coating (cm)
Catalogue
number
Carnelian Support 18
0.018”
0.018” 90 1.8 2.6 60 445720
0.018” 90 1.8 2.6 60 445720
0.018” 135 1.8 2.6 100 445721
0.018” 150 1.8 2.6 120 445722
Carnelian Support DP
Distal puncture
0.014” 60 1.8 2.6 40 445716
0.014” 80 1.8 2.6 60 445717a
Carnelian Support HD
Hard shaft
0.014” 90 1.8 2.6 60 445713
0.014” 135 1.8 2.6 100 445714
0.014” 150 1.8 2.6 120 445715
Carnelian Support 14
0.014"
0.014” 90 1.8 2.6 60 445710
0.014” 110 1.8 2.6 80 445983a
0.014” 135 1.8 2.6 100 445711
0.014” 150 1.8 2.6 120 445712
Carnelian Support BTA
Below-the-ankle
0.014” 150 1.6 2.6 120 445718
aAvailable on pre-order

How can we help you?

I prefer to be contacted by
*Fields are mandatory.

References

*Excluding central circulatory system and neurovasculature; indicated as per IFU.

1. Tokai data on file; 2. For the Carnelian Support BTA compared to leading reinforced support catheters in the CE market; 3. Only for the Carnelian Support BTA.
HD = Hard; DP = Distal puncture; BTA = Below-the-ankle.

Carnelian is a trademark or registered trademark of Tokai Medical Products, Inc.